User's Manual

Motor assembly
6.1 Motor assembly
$OOGLPHQVLRQVLQPP
&RROLQJFRQQHFWLRQDGDSWHU
LVQRWLQFOXGHGLQWKHVFRSH
RIVXSSO\
&RROHUFRQQHFWLRQRSWLRQDO
6WDWRU
&RROHUFRQQHFWLRQRSWLRQDO
&RROLQJFRQQHFWLRQSODWH
LVSHUPDQHQWO\DWWDFKHGWR
WKHVWDWRU
&\OLQGHUKHDGVFUHZ
,620[$
7LJKWHQLQJWRUTXH
WR1P
Figure 6-3 Installing the cooling connection adapter 1FW629
6.1.3 Information on routing cables
The cables must be appropriately selected corresponding to the mechanical forces caused
by higher rates of acceleration and higher speeds. Further, they must be suitable for the
bending stresses that occur.
1FW6 Built-in torque motors
90 Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3