Configuring the motor
5.1 Procedure
0
HII
If the individual torques are stable in each section, the integral can be simplified to create a
totals formula (see also the following diagram).
0
HII
0
HII
Figure 5-3 Motor torque-time diagram
5.1.4 Selecting the motors
You can choose a suitable torque motor using the values determined for the peak torque
M
mMAX
and continuous torque M
eff
.
You must take the following factors into account when selecting motors:
Regarding the maximum torque M
MAX
, the motor should have a control reserve of approx.
10% vis-à-vis the required value M
mMAX
to prevent unwanted limiting effects if the control
loops are overshot.
The rated motor torque M
N
must be at least as high as the continuous torque value M
eff
determined for the duty cycle.
If certain general conditions (e.g. machining torque or frictional torque) are not known,
you are advised to plan for even larger reserves.
In addition to the requirements resulting from the duty cycle, mechanical installation
conditions may influence your choice of motor. For instance, the same motor torque can
often be generated in a long motor with a smaller diameter as well as in a short motor
with a larger diameter.
If more than one torque motor generates torque on one axes, the values of the peak and
continuous torques of the individual motors must be added together.