Technical data

Administration scenarios Setting up the FTP server
90
Check handset functionalities
Check whether the plugs at the two ends of the handset cable are in-
serted correctly (handset engaged) Æ page 10.
Carry out an Audio Loop test.
More information on “Audio Loop Test“ Æ page 67.
Æ page 41
Ensure that the handset microphone is not switched off.
For more information, see the operating instructions of the
optiPoint 410.
Start up not successful
Check whether one or more of the mentioned questions are valid for your
configuration:
Is the optiPoint 410 being run in a Æ VLAN ?
Enter the VLAN ID manually, or, if a Æ DHCP server is being used, set
the “VLAN Discovery ModeÆ page 81 on "DHCP" , so that the VLAN
ID transferred from the DHCP server is used.
More information on “Virtual LAN ID“ Æ page 81.
Æ page 24 Æ page 59
Is the optiPoint 410 being run behind a Æ Gateway?
Enter the Æ IP address of the Gateway in Æ Default Route.
Æ page 21 Æ page 58
Other configuration possibilities ...
Check LAN connection
Check whether the plugs at the two ends of the LAN cable are correct-
ly inserted (handset engaged) Æ page 10.
Check the connection with the help of the PING test.
More information on “PING Test“ Æ page 78.
Æ page 42 Æ page 61
Determine the software version
You can determine the version of the software that is running the
optiPoint 410, e.g., during a pending software update.
Æ page 39 Æ page 54