7.5.5 Description of the table “Conferees“
For the purposes of the below table, all conferees are referred to as members.
The table “Conferees“ recognizes the following data fields:
Field name Keyword Value range Dflt. val-
ue
Description
Ident. of conference iNo_Parent Valid ident. -1 The identifier of the conference to which the conferee belongs.
Ident. of subscriber iNo_Subs Valid ident. -1 Identifier of the subscriber who is a member (conferee) of this con-
ference.
Member-specific parame-
ters
iProperties s. description 0 Bit mask of the member-specific parameters:
Bit 00: Active participation
Bit 01: Master
Bit 02: PIN identification required
Bit 03: '*' key confirmation required
Bit 04: Conferee starts off on hold
Bit 05: Conferee starts off with microphone off
Bit 06: Conferee is always redialed
Bit 07: Conferee is dialed at conference start
+ If you set bit 01, be careful to also set bit 00 and 07,
but not bit 04 or 05.
+ Bit 02 and 03 are mutually exclusive.
Display position iDispPos 0..60 0 The display position of the conferee.
Table 7-7 The data fields of the table “Conferees“: