1.2 Hardware and Loadware NCUI
New loadware (PZKNCI40) is available for the boards NCUI2+ and NCUI4 in HiPath 4000 V4
and later versions.
1.3 General Information
● HG 3575 IPDA will be upgraded to HG 3550 architecture. Basic functionality will remain
the same. This hub serves as a basis for integrating other possible features.
● In contrast to HG 3500, there is no standby concept for HG 3575.
● The NCUI board is still configured with the AMO STMIB.
>
The NCUI2 can be used for the migration!
Board type Part number B channels
NCUI2+ Q2305-X35 60 B channels (2 DSPs)
NCUI2+ Q2305-X40 120 B channels (4 DSPs)
NCUI4 Q2324-X 60 B channels (2 DSPs)
NCUI4 Q2324-X10 120 B channels (5 DSPs)
Table 1-1 Supported NCUI boards
Board type Loadware Restricted B channels Full feature scope
NCUI2+ PZKNCI40 x Not possible
NCUI4 PZKNCI40 x
Table 1-2 Boards, loadware, B channels and feature scope