Technical data
Solutions
EN4442EN00EN_0002
© 2007 Siemens AG
Siemens
51
10 Solutions
Questions
10.1 Which boards can be used in a HiPath 4000 V4 as an HG3500?
STMI2 Q2316-X
STMI2 Q2316-X10
STMI4 Q2324-X500
STMI4 Q2324-X510
10.2 What must be considered for a setup of function blocks with the
AMO BFDAT?
If HG3570 functionality is part of the profile, it must be configured on the first position.
10.3 Which restriction exists if the HG3500 is working with the
function HG3550?
Only one trunking protocol can be used (H.323 or SIP).
10.4 Which function ID must be used with the AMO BCSU for a setup
of a Common Gateway board?
The function ID 1.
10.5 Which task the AMO STMIB has?
Administration of NCUI boards.
10.6 Which AMO for the administration of HG3530 doesn’t exist
anymore in the HiPath 4000 V4?
The AMO HFAB.