Technical data

Multiple-Feature Configuration
EN4442EN00EN_0002
© 2007 Siemens AG
Siemens
38
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3550,LINECNT=1,UNITS=1;
>>>>> WAML with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=WAML;
>>>>> HFA with 70 circuits and 70 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3530,LINECNT=70,BCHLCNT=70;
>>>>> Do not end configuration of block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=4,ANSW=NO;
Assignment for functional block 4
ADD-BCSU:TYPE=IPGW,LTG=1,LTU=1,SLOT=43,PARTNO=Q2316-X10,FCTID=1,FCT-
BLK=4,IPADDR=198.16.16.43;
H500: AMO BCSU STARTED
F89: THE GIVEN FUNCTIONAL BLOCK IS NOT COMPLETELY CONFIGURED.
PLEASE FINISH CONFIGURATION BY MEANS OF AMO_BFDAT FIRST.
AMO-BCSU -54 BOARD CONFIGURATION, SWITCHING UNIT
ADD NOT COMPLETED;
6.6.2 Completed configuration block
>>>>> End configuration of block
CHANGE-BFDAT:CONFIG=OK,FCTBLK=4,ANSW=YES;
>
If the configuration of a functional block with the AMO BFDAT is not completed, the
block cannot be assigned to any board with the AMO BCSU.
The functional block must be completely configured with the AMO BFDAT before the
command can be successfully run.