Technical data

Multiple-Feature Configuration
EN4442EN00EN_0002
© 2007 Siemens AG
Siemens
37
AMO CGWB not necessary because the IP address is already configured with the AMO BCSU.
The additional configuration of the IPDA (UCSU, APRT etc) must be done as before in HiPath
4000 V30.
6.4 Configuration of a HFA phone
Configuring HFA subscriber on the STMI2 board in 1-1-31 (BFDAT profile 2):
ADD-CGWB:LTU=1,SLOT=31,SMODE=NORMAL,IPADDR=198.16.16.54,NET-
MASK=255.255.255.0;
REST-BSSU:ADDRTYPE=PEN,LTU=1,SLOT=31,
ADD-SBCSU:STNO=7180,PEN=1-1-31-0,OPT=OPTI,CONN=IP2,COS1=33,COS2=30
,LCOSV1=9,LCOSV2=1,LCCOSD1=9,LCOSD2=1,STD=100;
6.5 Configuring SIP Trunking
Configuring SIP trunking on the STMI2 board in 1-1-61 (BFDAT profile 3):
ADD-CGWB:LTU=1,SLOT=55,SMODE=NORMAL,IPADDR=198.16.16.55,NET-
MASK=255.255.255.0,TRPRSIP=30;
The additional configuration of the IP Trunking Connection must be done as before in HiPath
4000 V30.
6.6 Completed and Uncompleted Functional Block
6.6.1 Uncompleted functional block
Functional block 4: Adding the functions IPDA (HG3570), IP trunking (HG3550), WAML and
HFA subscriber (HG3530)
ADD-BFDAT:FCTBLK=4,FUNCTION=HG3570&HG3550&WAML&HG3530,BRDBCHL=BCHAN120;
>>>>> IPDA with 30 B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=4,FUNCTION=HG3570,BCHLCNT=30;
>>>>> IP trunking with one circuit and one unit (=10 B channels)
>
Only one trunking protocol can be configured for each common gateway board.