Technical data

Multiple-Feature Configuration
EN4442EN00EN_0002
© 2007 Siemens AG
Siemens
36
Functional block 3
Functional block 3: IP trunking, HFA subscriber function (HG3530) and reserve HFA subscriber
(HG3530R)
ADD-BFDAT:FCTBLK=3,FUNCTION=HG3550&HG3530&HG3530R,BRDBCHL=BCHAN120;
>>>>> HFA with 80 circuits with 80 B channels and 20 reserve B channels
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3530,LINECNT=80,BCHLCNT=100;
>>>>> Reserve HFA subscriber with 20 circuits
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3530R,LINECNT=20;
>>>>> IP trunking with 10 circuits with one unit (=10 B channels)
CHANGE-BFDAT:CONFIG=CONT,FCTBLK=3,FUNCTION=HG3550,LINECNT=10,UNITS=1;
6.2 Configuring the Common Gateway Board with the AMO BCSU
Assignment for functional block 1
ADD-BCSU:TYPE=IPGW,LTG=1,LTU=2,SLOT=37,PARTNO=Q2316-X10,FCTID=1,FCT-
BLK=1,IPADDR=198.16.16.45;
Assignment for functional block 2
ADD-BCSU:TYPE=IPGW,LTG=1,LTU=1,SLOT=31,PARTNO=Q2316-X10,FCTID=1,FCT-
BLK=2,IPADDR=198.16.16.31;
Assignment for functional block 3
ADD-BCSU:TYPE=IPGW,LTG=1,LTU=1,SLOT=61,PARTNO=Q2316-X10,FCTID=1,FCT-
BLK=7,IPADDR=198.16.16.59;
Converting reserved HFA circuits to usable circuits
CHANGE-BCSU:TYPE=IPGW,LTG=1,LTU=1,SLOT=61,CHNGRSLN=13;
6.3 Configuration of a IPDA
Configuring of an IPDA on the STMI2 board in 1-1-37 (BFDAT profile 1):
>
The reserved HFA B channels must be specified during configuration of the HG3530
function as subscriber B channels are not accepted during reservation.