Technical data
Configuration Common Gateway
EN4442EN00EN_0002
© 2007 Siemens AG
Siemens
34
You can check the status with DISPLAY-BFDAT:FCTBLK=<number>;
If the configuration of the functional block is complete STATUS=OK is displayed.
If a configuration error is detected when the block configuration is complete, the functional
block must be deleted (DELETE-BFDAT:FCTBLK=<number>,ANSW=YES;) and reconfig-
ured.
If the configuration of a functional block is not complete STATUS=CONT is displayed. The
functional block may not be assigned to a board. This is refused by the AMO BCSU with
the Fault message F89.
Fault message F89
H500: AMO BCSU STARTED
F89: THE GIVEN FUNCTIONAL BLOCK IS NOT COMPLETELY CONFIGURED.
PLEASE FINISH CONFIGURATION BY MEANS OF AMO_BFDAT FIRST.
AMO-BCSU -54 BOARD CONFIGURATION, SWITCHING UNIT
ADD NOT COMPLETED;
5.3 Restrictions
● Only one trunking protocol can be configured for each board (AMO CGWB). There are no
restrictions on interworking with other functions.
● The entire board must be reconfigured if the changes are made to the configuration.