Technical data

Configuration Common Gateway
EN4442EN00EN_0002
© 2007 Siemens AG
Siemens
34
You can check the status with DISPLAY-BFDAT:FCTBLK=<number>;
If the configuration of the functional block is complete STATUS=OK is displayed.
If a configuration error is detected when the block configuration is complete, the functional
block must be deleted (DELETE-BFDAT:FCTBLK=<number>,ANSW=YES;) and reconfig-
ured.
If the configuration of a functional block is not complete STATUS=CONT is displayed. The
functional block may not be assigned to a board. This is refused by the AMO BCSU with
the Fault message F89.
Fault message F89
H500: AMO BCSU STARTED
F89: THE GIVEN FUNCTIONAL BLOCK IS NOT COMPLETELY CONFIGURED.
PLEASE FINISH CONFIGURATION BY MEANS OF AMO_BFDAT FIRST.
AMO-BCSU -54 BOARD CONFIGURATION, SWITCHING UNIT
ADD NOT COMPLETED;
5.3 Restrictions
Only one trunking protocol can be configured for each board (AMO CGWB). There are no
restrictions on interworking with other functions.
The entire board must be reconfigured if the changes are made to the configuration.