User's Manual
6 U3585-J-Z125-8-76
Changes made since the last version Preface
– SET/MODIFY-COSMOS-PARAMETER
The new MEASUREMENT-TIME operand can be used to specify the duration of the
monitoring process.
In the TSN operand, up to 16 TSNs can be specified.
In the TSN, USER-ID, JOB-NAME and CATEGORY operands, the last character
may be an asterisk (*).
– SET-SERVICETIME-PARAMETER
The DEVICES operand has been extended to accept 256 device names.
– SET-TASK-PARAMETER
The DEVICES operand has been extended to accept 64 device names.
– SHOW-ACTIVE/DEFINED-PARAMETER
The TYPE operand has been extended to include the new monitoring programs
BCAM-CONNECTION and DISK-FILE.
– START/STOP/CHANGE-MEASUREMENT-PROGRAM
The TYPE operand has been extended to include the new monitoring programs
BCAM-CONNECTION, DISK-FILE and HSMS.
● New, enhanced and obsolete user statements
– The SELECT-SYMMETRIX-CONTROLLER user statement (select the
SYMMETRIX controller for the SYMMETRIX-DEVICE report) has been included in
the manual for the first time.
– The REPORT user statement has been extended to include the values BCAM,
DISK_FILE (DFILE) and SYMMETRIX (SYM).
– The CHANNEL user statement is now obsolete, since the CHANNEL report can
now output follow-up screens.
● SM2 program interface
In the SM2GDAT macro, the variable ’unsigned long buffer_flags’ is now incompatible.
The BCAM-CONNCETION, CHANNEL-IO, DISK-FILE and HSMS data buffers are now
available.
● Changes to the SM2 output file
In SM2 output files with freely selectable file characteristics, the block length must be
16.
● Dynamic IO reconfiguration
SM2 recognizes a dynamic IO reconfiguration and, if necessary, automatically changes
the number of objects being monitored. This is described in a new section in chapter 2.
● The constraints on SR2000 have been incorporated. For further information, please
refer to section 5.8 of the manual "OSD-SVP V2.0 User Interfaces on Systems with
RISC Architecture" [20].