User's Manual
374 U3585-J-Z125-8-76
NPS0040 Messages
NPS0040 SM2 STXIT: CLASS=(&00), CODE=(&01), LOCATION=(&02). PROGRAM RUN ABORTED
(B) Routing code: R Weight: 99
Meaning
An error has occurred in the unprivileged program part of SM2.
CLASS: event class.
CODE: error weight.
LOCATION: program counter of the location at which the error occurred.
For further information on the STXIT routine see the ’Executive Macros’ manual.
NPS0041 TOO MUCH USERS WANT TO MONITOR THE SAME FILE
Meaning
Maximal 64 users can monitor the same file at the same time.
NPS0044 USER NOT AUTHORIZED TO MONITOR TASK. COMMAND REJECTED
(B) Routing code: R Weight: 99
Meaning
The SM2 administrator has not permitted task monitoring. As a result, monitoring of the
user task either cannot be started or can no longer be stopped by the user.
If the user himself started the monitoring of his task by means of a
/START-TASK-MEASUREMENT command, monitoring has already been terminated by the
SM2 administrator.
NPS0045 TASK ALREADY BEING MONITORED BY SM2
(B) Routing code: R Weight: 50
Meaning
Monitoring of the task has already been started either by the user via
the /START-TASK-MEASUREMENT command or by the SM2 administrator.
NPS0046 TASK MONITORING NOT INITIATED BY ’/START-TASK-MEASUREMENT’. COMMAND REJECTED
(B) Routing code: R Weight: 99
Meaning
Task monitoring cannot be terminated, either because it was not started by the
/START-TASK-MEASUREMENT command or because it has already been terminated in
the meantime (e.g. due to withdrawal of permission to monitor the task or to SM2
shutdown).
NPS0047 SPECIFIED TASK DOES NOT EXIST
Meaning
A TSN was specified for which no task exists.