User's Manual

U3585-J-Z125-8-76 219
SM2 reports BCAM CONNECTION report
Monitoring information
SET Name of the connection set
# CONNECTIONS Number of (active) connections in the connection set.
The computation includes only those connections that were active
both at the current monitoring time and at the end of the preceding
monitoring cycle.
IN/OUT Data sent and received
TSDU Number of TSDUs per second
TSDUs (Transport Data Service Units) correspond to application
jobs on BCAM.
DATA Average volume of data in KB per TSDU
BUFFER Amount of cache space occupied by unretrieved messages in KB
and as a percentage of the maximum buffer size.
This value describes the status at the end of the monitoring cycle,
and not the mean value over the entire monitoring cycle.
PWIN Number of packets without user data (Packet WINdow) per second
PDATA Number of packets with user data (Packet DATA) per second
SCOM Number of send jobs per second in the event of a resource
bottleneck (Send Call Over Maximum)
ZWR Number of packets with Zero Window Information per second, i.e.
where the partner application does not allow the sending of any
further data
INWAIT TIME Time between the display of a message and the retrieval of that
message from the application
REACT TIME Time between an application’s send call and the receive call which
immediately precedes it
INPROC TIME Time between the arrival of a message at BCAM and the retrieval of
that message by the application
OUTPROC TIME Time between a send call and the transfer of the last byte of a
message to the network
BUCKET Limit values in milliseconds of the ranges within which the
monitored data is arranged by order of magnitude.
> indicates overflow values.
COUNT Number of messages sent/received in the individual ranges