pxxxx[0...n] Parameter number
The parameter number is made up of a "p" or "r", followed by the parameter num-
ber and the index or bit array (optional).
Examples of representation in the parameter list:
Other examples of the notation in the documentation:
The following applies to adjustable parameters:
The parameter value as delivered is specified under "Factory setting" with the rel-
evant unit in square brackets. The value can be adjusted within the range defined
by "Min" and "Max".
The term "linked parameterization" is used in cases where changes to adjustable
parameters affect the settings of other parameters.
Linked parameterization can occur, for example, as a result of the following
actions and parameters:
• Setting PROFIBUS telegram (BICO interconnections)
p0922
• Setting component lists
p0230, p0300, p0301, p0400
• Automatic calculation and pre-assignment
p0340, p3900
• Restoring factory settings
p0970
• p... Adjustable parameter (read and write)
• r... Display parameter (read-only)
• p0918 Adjustable parameter 918
• p2051[0...13] Adjustable parameter 2051, indices 0 to 13
• p1001[0...n] Adjustable parameter 1001, indices 0 to n (n = configurable)
• r0944 Display parameter 944
• r2129.0...15 Display parameter 2129 with bit array from bit 0 (smallest bit)
to bit 15 (largest bit)
• p1070[1] Adjustable parameter 1070, index 1
• p2098[1].3 Adjustable parameter 2098, index 1 bit 3
• p0795.4 Adjustable parameter 795, bit 4