User Manual

Parameters
BICO parameters (connectors/binectors)
1-486
© Siemens AG 2008 - 2013 All Rights Reserved
SINAMICS G120 CU230P-2 Control Units List Manual (LH9), 01/2013
1.4.5 Connector/binector outputs (CO/BO)
Product: SINAMICS G120, Version: 4601800, Language: eng, Type: CO/BO
r0046.0...31 CO/BO: Missing enable sig / Missing enable sig
r0050.0...1 CO/BO: Command Data Set CDS effective / CDS effective
r0051.0...1 CO/BO: Drive Data Set DDS effective / DDS effective
r0052.0...15 CO/BO: Status word 1 / ZSW 1
r0053.0...11 CO/BO: Status word 2 / ZSW 2
r0054.0...15 CO/BO: Control word 1 / STW 1
r0055.0...15 CO/BO: Supplementary control word / Suppl STW
r0056.0...15 CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
r0056.0...13 CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
r0722.0...12 CO/BO: CU digital inputs status / CU DI status
r0723.0...12 CO/BO: CU digital inputs status inverted / CU DI status inv
r0835.2...8 CO/BO: Data set changeover status word / DDS_ZSW
r0836.0...1 CO/BO: Command Data Set CDS selected / CDS selected
r0837.0...1 CO/BO: Drive Data Set DDS selected / DDS selected
r0863.1 CO/BO: Drive coupling status word/control word / CoupleZSW/STW
r0898.0...10 CO/BO: Control word sequence control / STW seq_ctrl
r0899.0...11 CO/BO: Status word sequence control / ZSW seq_ctrl
r1099.0 CO/BO: Skip band status word / Skip band ZSW
r1198.0...15 CO/BO: Control word setpoint channel / STW setpoint chan
r1199.0...8 CO/BO: Ramp-function generator status word / RFG ZSW
r1204.0...13 CO/BO: Flying restart U/f control status / FlyRest Uf st
r1205.0...15 CO/BO: Flying restart vector control status / FlyRest vector st
r1214.0...15 CO/BO: Automatic restart status / AR status
r1239.8...13 CO/BO: DC braking status word / DCBRK ZSW
r1261.0...7 CO/BO: Bypass control/status word / Bypass STW / ZSW
r1407.0...17 CO/BO: Status word speed controller / ZSW n_ctrl
r1408.0...14 CO/BO: Status word current controller / ZSW I_ctrl
r2129.0...15 CO/BO: Trigger word for faults and alarms / Trigger word
r2135.12...15 CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
r2138.7...15 CO/BO: Control word faults/alarms / STW fault/alarm
r2139.0...12 CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1
r2197.0...13 CO/BO: Status word monitoring 1 / ZSW monitor 1
r2198.4...12 CO/BO: Status word monitoring 2 / ZSW monitor 2
r2199.0...5 CO/BO: Status word monitoring 3 / ZSW monitor 3
r2225.0 CO/BO: Technology controller fixed value selection status word / Tec_ctr FixVal ZSW
r2349.0...12 CO/BO: Technology controller status word / Tec_ctrl status
r2379.0...7 CO/BO: Closed-loop cascade control status word / Csc_ctrl ZSW
r2399.0...8 CO/BO: Energy-saving mode status would / En_save ZSW
r3113.0...15 CO/BO: NAMUR message bit bar / NAMUR bit bar
r3333.0...3 CO/BO: 2/3 wire control control word / 2/3 wire STW
r3859.0 CO/BO: Compound braking status word / Compound Br ZSW
r3889.0...9 CO/BO: ESM status word / ESM ZSW
r4022.0...3 CO/BO: PM330 digital inputs status / PM330 DI status
r4023.0...3 CO/BO: PM330 digital inputs status inverted / PM330 DI stat inv
r5613.0...1 CO/BO: Pe energy-saving active/inactive / Pe save act/inact
r8795.0...15 CO/BO: CAN control word / Control word
r11049.0...11 CO/BO: Free tec_ctrl 0 status word / Ftec0 stat_word
r11149.0...11 CO/BO: Free tec_ctrl 1 status word / Ftec1 stat_word
r11249.0...11 CO/BO: Free tec_ctrl 2 status word / Ftec2 stat_word