User Manual
List of parameters
Parameters
1-207
© Siemens AG 2008 - 2013 All Rights Reserved
SINAMICS G120 CU230P-2 Control Units List Manual (LH9), 01/2013
Description: Sets the proportional gain of the controller for speed adaptation without encoder.
Description: Sets the integral time of the controller for speed adaptation without encoder
Description: Displays the P component of the controller for speed adaptation.
Description: Displays the I component of the controller for speed adaptation.
Description: Sets the offset voltage in the alpha direction; this compensates the offset voltages of the drive converter/inverter at
low speeds. The value is valid for the rated (nominal) pulse frequency of the power unit.
Note: The value is pre-set during the rotating measurement.
p1764[0...n] Motor model without encoder speed adaptation Kp / MotMod woE n_adaKp
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6730
Min Max Factory setting
0.000 100000.000 1000.000
p1767[0...n] Motor model without encoder speed adaptation Tn / MotMod woE n_adaTn
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6730
Min Max Factory setting
1 [ms] 200 [ms] 4 [ms]
r1770 CO: Motor model speed adaptation proportional component / MotMod n_adapt Kp
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Units group: 3_1 Unit selection: p0505 Func. diagram: 6730
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r1771 CO: Motor model speed adaptation I comp. / MotMod n_adapt Tn
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Units group: 3_1 Unit selection: p0505 Func. diagram: 6730
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
p1774[0...n] Motor model offset voltage compensation alpha / MotMod offs comp A
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
-5.000 [V] 5.000 [V] 0.000 [V]