User Manual
SINAMICS G120 CU230P-2 Control Units
List Manual (LH9), 04/2014, A5E33838102B AA
561
3 Function diagrams
3.8 Internal control/status words
Fig. 3-56 2537 – Status word, monitoring functions 3
- 2537 -
Function diagram
87654321
fp_2537_97_01.vsd
Internal control/status words
G120 CU230P-2
07.04.2014 V4.7
Status word, monitoring functions 3
11
12
13
14
15
PROFIdrive-Bit
9
10
8
7
6
5
4
3
2
1
0
r2199.5
r2199.1
r2199.0
[8012.1]
r2199.4
From speed signals
<1> n_act = smoothed speed actual value r2169 [8010.2].
Status word, monitoring functions 3 (r2199)Bit No.
1 = |n_act| < speed threshold value 3 (p2161)
1 = f or n comparison value reached or exceeded (p2141)
1 = Speed setpoint - actual value deviation within tolerance t_on
1 = Ramp-up/ramp-down completed
0 = Ramp-function generator active
ZSW monitor 3
r2199
r2199
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
[8010.8]
From speed signals [8011.8]
From speed signals [8011.8]
From speed signals [8010.8]
Reserved
Reserved
<1>