Only users with administrator privileges can change the options.
Timeout in Seconds
This option indicates how long the image scan by the sensor is to run before the application
aborts capture.
Values between 1 and 200 are permitted.
The factory default setting is 20.
Minimum Length
This option indicates the minimum number of characters required for the logon password.
Values between 0 and 40 are permitted.
Security Level
In the case of the security level, a distinction is made between "Normal" and "Extended". The
"Normal“ setting gives you a high level of security and recognition. You should only use the
"Extended" security mode if you require a significantly higher level of security.
Attention: Selecting "Extended" may cause an increased number of fingerprints to be
rejected!
The factory default setting is "Normal“.
Logon mode
You can select either "Fingerprint“ or "Fingerprint or User ID and Password" as your logon
mode. If you select "Fingerprint“, logon on can only be performed using a fingerprint and not
by entering a user ID and password.
The default factory setting "Fingerprint or User ID and Password".
If you select the "Fingerprint" option and the sensor is defective, you will not be
able to access the system.
There is also an option that indicates that the PC is to be shut down automatically if an error
indicating manipulation occurs when logging on to the PC. If only the fingerprint identification
fails, this mechanism has no effect.
By default, this option is disabled.