Specifications
AT Command Set for L55 Platform 2003-11-21
Copyright Siemens AG 2003 All Rights Reserved Page 102 of 131
2.4.2.22 AT^SPBS
AT^SPBS Select a telephone book (including Siemens-specific books)
Test command
AT^SPBS=?
Response
^SPBS: (list of supported <sto>s)
OK/ERROR/+CME ERROR
Parameter
<sto>
FD SIM fix-dialing telephone book
SM SIM telephone book
ME Telephone book in device
DC ME Dialled Calls List
ON Own telephone numbers
LD SIM last dialing number
MC ME Missed Calls List
RC ME Received Calls List
MD Last number redial memory in telephone device
OW Own numbers
BD Barred dialing numbers
SD Service dialing numbers
MS Missed dialing numbers (unanswered calls)
CD Callback dialing numbers (answered calls)
BL Blacklist dialing numbers (barred numbers from remote)
MB Mailbox dialing numbers (network-operator mailbox)
CS Common sortable telephone book (sorted combination of
“SM”, ”ME”, ”FD”; access only via ^SPBC, ^SPBG)
RD Red book (all entries in ”CS” whose name portions have an
exclamation mark (‘!’) as their final character)
*For detailed information on the telephone-book features see “Appendix A”
Read command
AT^SPBS?
Response
^SPBS: <sto>>[,<used>,<total>]
OK/ERROR/+CME ERROR
Parameter
<sto>
See Test command
<used> integer type value indicating the number of used locations in
selected memory
<total> integer type value indicating the total number of locations in
selected memory
Write command
AT^SPBS=<sto>
Parameter
<sto>
See Test command
Response
OK/ERROR/+CME ERROR
2.4.2.23 AT^SPIC
AT^SPIC Output PIN counter
Test command
AT^SPIC=?
Response
OK/ERROR/+CME ERROR
Execute command
AT^SPIC
Response
^SPIC: <counter>
OK/ERROR/+CME ERROR
Parameter
<counter>
Number of attempts still available to enter the <passwd>.
Use the AT+CPIN? command to check which password is
being required.