2.4.2.20 AT^SPBC
AT^SPBC Seek the first entry in the sorted telephone book which begins with the selected
(or next available) letter
Test command
AT^SPBC=?
Response
^SPBC: (list of sorted telephone books supported <mem>s)
See AT+CPBS / AT^SPBS
OK/ERROR/+CME ERROR
Write command
AT^SPBC=<char>
Parameter
<char>
First letter of desired entry
Value range: letters A to Z (capitals only)
(if <char> is not A to Z, the index of the first entry
beginning with a special character is displayed)
<index> Index in the sorted telephone book (access via
AT^SPBG)
Response
^SPBC: <index>
OK/ERROR/+CME ERROR
2.4.2.21 AT^SPBG
AT^SPBG Read entry from the sorted telephone book via the sorted index
Test command
AT^SPBG=?
Response
^SPBG: (list of supported <index>s), <nlength>, <tlength>
OK/ERROR/+CME ERROR:
Parameter
<index>
Location number
<nlength> Max. length of telephone number
<tlength> Max. length of the text corresponding to the number
Write command
AT^SPBG=
<index1>
[, <index2>]
Response
^SPBG:<index1>,<number>,<type>,<text>[<CR><CL>
^SPBG: .....
^SPBG:<index2>,<number>,<type>,<text>]
OK/ERROR/+CME ERROR
Parameter
<index1>
Location number where the read of the entry starts
<index2> Location number where the read of the entry ends
<number> Telephone number
<type> Type of number