Operating instructions

MM420 Parameter List 04/02
MICROMASTER 420 Parameter List
90 6SE6400-5BA00-0BP0
r2033 BO: CtrlWrd2 from BOP link (USS) Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays control word 2 from BOP link (i.e. word 4 within USS).
Bitfields:
Bit00 Fixed frequency Bit 0 0 NO
1 YES
Bit01 Fixed frequency Bit 1 0 NO
1 YES
Bit02 Fixed frequency Bit 2 0 NO
1 YES
Bit08 PID enabled 0 NO
1 YES
Bit09 DC brake enabled 0 NO
1 YES
Bit13 External fault 1 0 YES
1NO
Dependency:
P0700 = 4 (USS on BOP link) and P0719 = 0 (Cmd / Setpoint = BICO parameter).
r2036 BO: CtrlWrd1 from COM link (USS) Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays control word 1 from COM link (i.e. word 1 within USS).
Bitfields:
Bit00 ON/OFF1 0 NO
1 YES
Bit01 OFF2: Electrical stop 0 YES
1NO
Bit02 OFF3: Fast stop 0 YES
1NO
Bit03 Pulse enable 0 NO
1 YES
Bit04 RFG enable 0 NO
1 YES
Bit05 RFG start 0 NO
1 YES
Bit06 Setpoint enable 0 NO
1 YES
Bit07 Fault acknowledge 0 NO
1 YES
Bit08 JOG right 0 NO
1 YES
Bit09 JOG left 0 NO
1 YES
Bit10 Control from PLC 0 NO
1 YES
Bit11 Reverse (setpoint inversion) 0 NO
1 YES
Bit13 Motor potentiometer MOP up 0 NO
1 YES
Bit14 Motor potentiometer MOP down 0 NO
1 YES
Bit15 Local / Remote 0 NO
1 YES
Details:
See r2033 (control word 2 from BOP link).
Level:
3
Level: