Operating instructions
MM420 Parameter List 04/02
MICROMASTER 420 Parameter List
88 6SE6400-5BA00-0BP0
P2019[4] CI: PZD to COM link (USS) Min: 0:0
CStat: CT Datatype: U32 Unit: - Def: 52:0
P-Group: COMM Active: Immediately QuickComm. No Max: 4000:0
Displays process data received via USS on COM link.
STXLGEADRBCC
 USS telegram
P2012
Parameter
Process data
PKWPZD
PZD mapping from parameter P2019
PZD1
ZSW1
PZD2
HIW
PZD3PZD4
ZSW2
USS on COM link
[0]
P2019
[1]
[2]
[3]
STX
LGE
ADR
Start of text
Length
Address
PKW
PZD
BCC
Parameter ID value
Process data
Block check character
ZSW
HIW
Status word
Main actual value
r0021
r0052
r0052
r0053
r0053
Index:
P2019[0] : Transmitted word 0
P2019[1] : Transmitted word 1
P2019[2] : Transmitted word 2
P2019[3] : Transmitted word 3
Details:
See P2016 (PZD to BOP link)
r2024[2] USS error-free telegrams Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays number of error-free USS telegrams received.
Index:
r2024[0] : Serial interface COM link
r2024[1] : Serial interface BOP link
r2025[2] USS rejected telegrams Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays number of USS telegrams rejected.
Index:
r2025[0] : Serial interface COM link
r2025[1] : Serial interface BOP link
r2026[2] USS character frame error Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays number of USS character frame errors.
Index:
r2026[0] : Serial interface COM link
r2026[1] : Serial interface BOP link
r2027[2] USS overrun error Min: -
Datatype: U16 Unit: - Def: -
P-Group: COMM Max: -
Displays number of USS telegrams with overrun error.
Index:
r2027[0] : Serial interface COM link
r2027[1] : Serial interface BOP link
Level:
3
Level:
3
Level:
3
Level:
3
Level:
3