Operating instructions

04/02 1 Parameters
MICROMASTER 420 Parameter List
6SE6400-5BA00-0BP0
75
However priorities are allocated to these parameters as follows:
P1310 > P1311 > P1312
Notice:
Increasing the boost levels increases motor heating (especially at standstill).
å
ImotR300Boosts S
P1311 Acceleration boost Min: 0.0
CStat: CUT Datatype: Float Unit: % Def: 0.0
P-Group: CONTROL Active: Immediately QuickComm. No Max: 250.0
P1311 will only produce boost during ramping, and is therefore useful for additional torque during
acceleration and deceleration.
Applies boost in [%] relative to P0305 (rated motor current) following a positive setpoint change and drops
back out once the setpoint is reached.
Vmax
Vn
(P0304)
V
AccBoost,100
0
fn
(P0310)
fmax
(P1082)
f
V
f
Boost,end
(P1316)
V
AccBoost,50
Boost
Linear V/f
O
u
t
p
u
t
v
o
l
t
a
g
e
actual V
N
o
r
m
a
l
V
/
f
(
P
1
3
0
0
=
0
)
where voltage values are given
V_AccBoost,100 = rated motor current (P0305) * Stator resistance (P0350) * Acceleration boost (P1311)
V_AccBoost,50 = V_AccBoost,100 / 2
Dependency:
Setting in P0640 (motor overload factor [%]) limits boost.
Note:
Acceleration boost can help to improve response to small positive setpoint changes.
å
ImotR300Boosts S
Notice:
Increasing the boost level increases motor heating.
Details:
See note in P1310 for boost priorities.
Level:
2