Operating instructions

04/02 1 Parameters
MICROMASTER 420 Parameter List
6SE6400-5BA00-0BP0
57
P1082 Max. frequency
Min: 0.00
CStat: CT Datatype: Float Unit: Hz Def: 50.00
P-Group: SETPOINT Active: first confirm QuickComm. Yes Max: 650.00
Sets maximum motor frequency [Hz] at which motor will run irrespective of the frequency setpoint.
Dependency:
The maximal value of motor frequency P1082 is limited to pulse frequency P1800. P1082 is dependent on
the derating characteristic as followed:
Max. frequency
P1082
133.3
650.0
21016
f
max
[Hz]
f
pulse
[kHz]
Allowed
area
15
1800P
15
f
P1082 f
pulse
max ==
Pulse
frequency
P1800
When P1300 < 20 (control mode = VF or FCC modes) then max output frequency is limited to smallest of
650 Hz or ( maximum pulse frequency / 15)
Note:
The value set here is valid for both clockwise and anticlockwise rotation.
The maximum output frequency of inverter can be exceeded if one of the following is active:
Flying restart
Slip compensation
or
=
=
maxcompslipmax ff +
nomslipmax ff +
Notice:
Maximum motor speed is subject to mechanical limitations.
Level: