Operating instructions

MM420 Parameter List 04/02
MICROMASTER 420 Parameter List
124 6SE6400-5BA00-0BP0
- 3200 -
Function diagram
87654321
3200_FF.vsd
Internal Setpoint Source
MICROMASTER 420
02.04.2002 V1.13
Fixed Frequency (FF) bit coded
r1024
CO: Act. FF
Fixed frequency 2
-650.00 ... 650.00 [Hz]
P1002 (5.00)
1
Fixed frequency 3
-650.00 ... 650.00 [Hz]
P1003 (10.00)
(0:0)
BI: FF sel. Bit 0
P1020
0
3
1,2
FF mode - Bit 0
1 ... 3
P1016 (1)
0
3
1,2
(0:0)
BI: FF sel. Bit 1
P1021
FF mode - Bit 1
1 ... 3
P1017 (1)
0
3
1,2
(0:0)
BI: FF sel. Bit 2
P1022
FF mode - Bit 2
1 ... 3
P1018 (1)
Fixed frequency 1
-650.00 ... 650.00 [Hz]
P1001 (0.00)
0
0
1
0
0
1
0
0
1
++
2
1
0
FF mode - Bit 0
1 ... 3
P1016 (1)
2
1
0
FF mode - Bit 1
1 ... 3
P1017 (1)
2
1
0
FF mode - Bit 2
1 ... 3
P1018 (1)
(P1016 - P1018 = 1 or 2)
ON/OFF1