Operating instructions

6 Troubleshooting Issue B1
MICROMASTER 420 Operating Instructions
72 6SE6400-5AA00-0BP0
6.4 MICROMASTER 420 alarm messages
Fault Possible Causes Diagnose & Remedy Reac-
tion
A0501
Current Limit
Ø Motor power does not correspond
to the inverter power
Ø Motor leads are too short
Ø Earth faults
1. Check whether the motor power corresponds
to the inverter power
2. Check that the cable length limits have not
been exceeded
3. Check motor cable and motor for short-
circuits and earth faults
4. Check whether the motor parameters
correspond with the motor being used
5. Check the stator resistance
6. Increase the ramp-up-time
7. Reduce the boost
8. Check whether the motor is obstructed or
overloaded
--
A0502
Overvoltage
limit
Ø Mains supply too high
Ø Load regenerative
Ø Ramp-down time too short
1. Check that mains supply voltage is within
allowable range
2. Increase ramp down times
Note:
Vdc-max controller is active, ramp-down times will
be automatically increased
--
A0503
Undervoltage
Limit
Ø Mains supply too low
Ø Short mains interruption
Check main supply voltage (P0210) --
A0504
Inverter Over-
temperature
Warning level of inverter heat-sink
temperature (P0614) is exceeded,
resulting in pulse frequency reduction
and/or output frequency reduction
(depending on parametrization in
(P0610)
1. Check if ambient temperature is within
specified limits
2. Check load conditions and duty cycle
3. Check if fan is turning when drive is running
--
A0505
Inverter I
2
t
Warning level is exceeded; current
will be reduced if parameterized
(P0610 = 1)
Check if duty cycle is within specified limits --
A0506
Inverter Duty
Cycle
Heatsink temperature and thermal
junction model are outside of
allowable range
Check if duty cycle are within specified limits --
A0511
Motor Over-
temperature I
2
t
Motor overloaded Check the following:
1. P0611 (motor i
2
t time constant) should be set
to appropriate value
2. P0614 (Motor i
2
t overload warning level)
should be set to suitable level
3. Are long periods of operation at low speed
occuring
4. Check that boost settings are not too high
--
A0541
Motor Data
Identification
Active
Motor data identification (P1910)
selected or running
Wait until motor identification is finished --
A0600
RTOS Overrun
Warning
Software error
A0700
CB warning 1
CB (communication board) specific See CB user manual --
A0701
CB warning 2
CB (communication board) specific See CB user manual --
A0702
CB warning 3
CB (communication board) specific See CB user manual --
A0703
CB warning 4
CB (communication board) specific See CB user manual --
A0704
CB warning 5
CB (communication board) specific See CB user manual --
A0705
CB warning 6
CB (communication board) specific See CB user manual --