17.3 AT^SBC Battery charge and charger control
Please note that the AT^SBC command is intended only for use the MC35i Module. It is not relevant for the MC35i
Terminal.
If the product is MC35i Module: The
AT^SBC read command can be used to query the average current consump-
tion of the module. The
AT^SBC write command determines the presentation of Unsolicited Result Codes used
to indicate undervoltage conditions.
Syntax
Unsolicited Result Code
^SBC: Undervoltage
The URC will be sent if undervoltage is detected. If the module is in IDLE mode it takes typically one minute to
deregister from the network and to switch off.
Test Command
AT^SBC=?
Response(s)
^SBC:(list of supported <bcs>s), (list of supported <bcl>s), (list of supported <mpc>s)
OK
Read Command
AT^SBC?
Response(s)
^SBC: <bcs>, <bcl>, <mpc>
OK
ERROR
+CME ERROR: <err>
Write Command
AT^SBC=<n>
Response(s)
OK
ERROR
+CME ERROR: <err>