2.1 AT&F Set all current parameters to manufacturer defaults
AT&F sets all current parameters to the manufacturer defined profile.
Syntax
Parameter Description
[0] Set all TA parameters to manufacturer defaults
Notes
List of parameters reset to manufacturer default can be found in Section 19.5, Factory Default Set-
tings Restorable with AT&F
.
In addition to the default profile, you can store an individual one with
AT&W. To alternate between the two pro-
files enter either
ATZ (loads user profile) or AT&F (restores factory profile).
Every ongoing or incoming call will be terminated.
Exec Command
AT&F[<value>]
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
V.25ter
<value>
(num)