Specifications

MC35i AT Command Set
8.12 AT^SPLW
s
m
obil
e
MC35i_ATC_V01.03 Page 194 of 444 5/7/04
Confidential / Released
8.12 AT^SPLW Write an entry to the preferred operators list
Syntax
Command Description
Test command returns the whole index range supported by the SIM.
Write command writes an entry to the SIM list of preferred operators at location number
<index>. If <index>
is given but <oper> is left out, the entry is deleted. An operator can be only once in the list.
Parameter Description
location number
Operator in numeric format (GSM Location Area Identification number which consists of a 3-digit country code
plus a 2- or 3-digit network code).
Note
See also GSM 07.07: AT+CPOL
Test Command
AT^SPLW=?
Response(s)
^SPLW:(list of supported) <index>s
OK
ERROR
+CME ERROR:
Write Command
AT^SPLW=<index>[, <oper>]
Response(s)
OK
ERROR
+CME ERROR: <err>
PIN ASC0 MUX1 MUX2 MUX3
% % % % %
Reference(s)
SIEMENS
<index>
(num)
<oper>
(str)