Specifications

MC35i AT Command Set
7.12 ATS7
s
m
obil
e
MC35i_ATC_V01.03 Page 146 of 444 5/7/04
Confidential / Released
7.12 ATS7 Set number of seconds to wait for connection completion
Syntax
Command Description
This parameter specifies the amount of time, in seconds, that the ME shall allow between either answering a call
(automatically or by the A command) or completion of signalling of call addressing information to network (dial-
ling), and establishment of a connection with the remote DCE.
Parameter Description
no. of seconds to wait for connection completion
000...060
(&F)
Notes
Values bigger than 60 cause no error, but <n> will be set down to maximum value of 60.
•In
<n> of ATS0 of the called party is set to higher values the call establishment may not be successful.
The correlation between
ATS7 and ATS0 is important.
Example: ATS7=30 and ATS0=20 may not allow call establishment.
Read Command
ATS7?
Response(s)
<n>
OK
Write Command
ATS7=<n>
Response(s)
OK
ERROR
PIN ASC0 MUX1 MUX2 MUX3
! % % ! !
Reference(s)
V.25ter
<n>
(num)(&W)(&V)