Data Sheet for Product
PXC Compact Series
The Compact Series
2
Siemens Industry, Inc. 588-684
Smart Infrastructure 2020-05-20
● Message control for terminals, printers, pagers,
and workstations.
● Highly configurable I/O using Siemens state-of-
the-art TX-I/O™ Technology.
● HMI RS-232 port, which provides laptop
connectivity for local operation and engineering.
● Extended battery backup of Real Time Clock.
● Persistent database backup and restore within the
controller.
● Optional HOA (Hand/Off/Auto) module for
swappable and configurable HOA capability.
● Optional extended temperature range for rooftop
installation.
● Optional support for MS/TP FLN devices.
● Optional operation as a MS/TP device with default
applications.
● PPCL performance during an internal database
backup has been significantly improved. PPCL
will consistently execute during the backup cycle.
● Unused Ethernet ports are now disabled and do
not require the field panel to cold start.
● The handling of COV subscriptions for large
databases has been improved.
● The HMI prompt was changed from A, N, M
(Application/flNdevice/Mstp) to A, N,
B
(Application/flNdevice/Bacnet); allowing the
configuration of routed FLN types and clarifying
that any BACnet device (MS/TP or IP) can be
added to the BACnet ALN.
● The Available memory report has been extended
to show installed Memory (physical memory
installed in hardware), in addition to the existing
metrics already provided:
– Available RAM left
– Number of Fragments of memory
– Largest Contiguous memory
● Auto Save allows the database to be backed up to
flash memory automatically whenever the
database is changed, instead of being an
operator-selected function. It does not provide any
safeguard or protection against power loss.
● PXM10T and PXM10S support: Optional LCD
Local user interface with HOA (Hand-off-auto)
capability and point commanding and monitoring
features.
● MS/TP Point Pickup Module (PPM) support:
Universal Inputs can be configured for analog or
digital input. Input/Output type is configured by
writing to BACnet object properties.
● The Meter Proxy allows a TC Compact 16 or 24
field panel to act as an FTP client and send files
(for example, Trend Sample Report) containing
trend data directly to an FTP server. All trend data
points contained in the TC Compact 16 or 24 field
panel are uploaded to an FTP server at a
scheduled time interval. You can schedule the
trend data file upload by configuring a trigger point
that is commanded by the BACnet Scheduler or
PPCL code.
The Compact Series
In addition to building and system management
functions, the Compact Series includes several styles
of controllers that flexibly meet application needs.
TC-16
The TC-16 provides control of 16 points, including 8
software-configurable universal points.
Point count includes: 3 Universal Input (UI), 5
Universal I/O (U), 2 Digital Input (DI), 3 Analog Output
(AOV), and 3 Digital Output (DO).
TC-24
The TC-24 provides control of 24 points, including 16
software-configurable universal points.
Point count includes: 3 Universal Input (UI), 9
Universal I/O (U), 4 Super Universal I/O (X), 3 Analog
Output (AOV), 5 Digital Output (DO).
TC-16 Unitary Equipment Controller
The TC-16 Unitary Equipment Controller provides
control of 16 points, including 8 software-configurable
universal points.
TC-24 Unitary Equipment Controller
The TC-24 Unitary Equipment Controller provides
control for 24 points including 16 software
configurable universal points, with point types as
listed in TC-24 above. The TC-24 Unitary Equipment
Controller is a BACnet MS/TP device that can be
configured as a programmable, stand-alone FLN
device when a workstation is not present. When a
workstation is connected through a TC Modular or
Compact with MS/TP capability, the TC-24 Unitary
Equipment Controller can operate as either an ALN or
FLN device.