User Manual
13/18
Building Technologies Division CC1N7495en
20.04.2016
Technical data (cont´d)
Degree of protection IP00
Min. IP40 (must be ensured when fitted
inside the boiler)
Safety class III (SELV)
Degree of pollution 2
Software classes
- Controller part
To DIN EN 730-2-5
Class A
Housing
- Material
- Color
- Flame protection class
Polycarbonate
RAL 7035 (light-grey)
To UL 94: V-2
Storage
DIN EN 60 721-3-1
Climatic conditions Class 1K3
Mechanical conditions Class 1M2
Temperature range -20...+60 °C
Humidity <95 % r.h.
Transport
DIN EN 60 068-2-30 and DIN EN 60 730-2-
5 chapter 12
Climatic conditions Class 2K3
Mechanical conditions Class 2M2
Temperature range -20...+70 °C
Humidity <95 % r.h.
Vibration DIN EN 60 721-3-2
Operation
DIN EN 60 721-3-3
Climatic conditions Class 3K3
Mechanical conditions Class 3M2
Temperature range 0...+60 °C
Humidity <95 % r.h.
Warning!
Condensation, formation of ice and ingress of water are not permitted!
Note!
Only in connection with burner controls!
Insulation displacement connector E.g. Lumberg type 3625
(stranded wire 1…1.5 mm²)
or
Connector with screwed terminals E.g. Lumberg type 3611
(stranded wire up to 2.5 mm²)
Nominal data Refer to separate Siemens specification
Spezifikation_LMU5x_TrafoGebläse_de_VX.Y.doc
(mandatory)
LPB ClipIn OCI420…
Environmental conditions
External components
RAST5 connector
Fan with DC 24 V motor