User Manual
12/18
Building Technologies Division CC1N7495en
20.04.2016
Technical data (cont´d)
Free programmable
- Voltage
- Current
- Mains frequency
AC 230 V +10 % / -15 %
5 mA…1 A, cos >0.8
50 Hz ±5 %
With regard to the outputs, the total current draw of the LMU7... system must be taken
into consideration!
Degree of protection IP00
Min. IP40 (to be ensured when fitted in-
side the boiler)
Safety class Parts of safety class 0 and of SELV
Degree of pollution 2
Software classes
- Controller part
To DIN EN 730-2-5
Class A
Housing
- Material
- Color
- Flame protection class
Polycarbonate
RAL 7035 (light-grey)
To UL 94: V-2
Storage
DIN EN 60 721-3-1
Climatic conditions Class 1K3
Mechanical conditions Class 1M2
Temperature range -20...+60 °C
Humidity <95 % r.h.
Transport
DIN EN 60 068-2-30 and DIN EN 60 730-2-
5 chapter 12
Climatic conditions Class 2K3
Mechanical conditions Class 2M2
Temperature range -20...+70 °C
Humidity <95 % r.h.
Vibration DIN EN 60 721-3-2
Operation
DIN EN 60 721-3-3
Climatic conditions Class 3K3
Mechanical conditions Class 3M2
Temperature range 0...+60 °C
Humidity <95 % r.h.
Warning!
Condensation, formation of ice and ingress of water are not permitted!
Note!
Only in connection with burner controls!
Collector sensor NTC 10 k
Solar ClipIn
AGU2.530A109
Outputs
Electrical connection
Note
Environmental conditions
Input