Switching actuators with load
current
detection N 535D
• One relay contact per output as a
switching element with load current
monitoring
• Contact rated current voltage
AC 230 V
• Contact rated frequency
50 / 60 Hz
• Per switch output with mechanical
switch position display, which can
also be used for manual control of
the switch output
• Maintenance-free terminals for
connecting and looping through
solid, stranded, and fine-stranded
conductors, 0.5 to 2.5 mm
2
• At least one phase connection
terminal per output
• Operation of electronics via bus
voltage
• Integrated bus coupler, bus connection
via bus terminal block
• Red LED for displaying the activation
of address mode and readiness for
operation
• Housing Plastic; color: RAL 7035
(light gray); N-dimension
• DIN rail-mounted device for installa-
tion on rail TH35 DIN EN 60715
• Protection type: IP 20
• Switching construction site function
• Object for monitoring device
functionality
• Object for targeted call-up of status
values
• Control functions
• Selectable operating mode: normal
mode/timer mode/flashing
• Configurable relay operating mode
NC/NO
• Configurable on/off switch delay
• Logic operations (AND, OR, NOT
AND, EXCLUSIVE OR, NOT OR,
FILTER, TRIGGER)
• Configurable switching state for bus
voltage failure and starting value of
the switching object for when bus
voltage is recovered
• Addable night mode object for
time-limited switch-on of the
output, i.e., the lighting
Scene control
Integrated 8-bit scene control with up
to 8 scene assignments per output
Time functions
• Configurable ON time for night and/
or timer mode
• Addable object for the configuration
of the time limit in timer mode
• Selectable retriggering of ON time
(1x, 2x, 3x, 4x, 5x) for timer mode
• Selectable warning before switching
off by briefly switching off and back
on again
• Flashing with night or timer mode
and/or via an optional pre-warning
object
Override functions
• Manual override ON
• Permanent OFF
• Lock mode
• Forced switch-on/off
Diagnostic functions:
• Counting of operating hours with
threshold monitoring
• Counting of switching cycles with
threshold monitoring
• Load current detection with thresh-
old monitoring and identification
of contact errors
Shared
characteristics
Functions
per device
Type Design OC Order no. PE
(ST, SZ, M)
PKG/
VPE
PG Price
(€)
N 535D31 Switching actuator with LC 4 x AC 230 V,
16/20 AX, C-load
A 5WG1535-1DB31 1 1
N 535D51 Switching actuator with LC 8 x AC 230 V,
16/20 AX, C-load
A 5WG1535-1DB51 1 1
N 535D61 Switching actuator with LC 12 x AC 230 V,
16/20 AX, C-load
A 5WG1535-1DB61 1 1
New