Instruction manual
 General information en
13
KGeneral information
General information
Exhaust air mode
:Warning
Risk of death!
Risk of poisoning from flue gases that are drawn back 
in. The exhaust air must not be conveyed into a 
functioning smoke or exhaust gas flue or into a shaft 
which is used to ventilate installation rooms that contain 
heating appliances. If the exhaust air is to be conveyed 
into a non-functioning smoke or exhaust gas flue, you 
must obtain the consent of the heating engineer 
responsible.
If the exhaust air is conveyed through the outer wall, a 
telescopic wall box should be used.
Exhaust duct
Note: The device manufacturer does not assume any 
warranty for complaints attributable to the pipe section.
■ The device achieves its optimum performance by 
means of a short, straight exhaust air pipe and as 
large a pipe diameter as possible.
■ As a result of long rough exhaust air pipes, many 
pipe bends or pipe diameters that are smaller than 
150 mm, the optimum extraction performance is not 
achieved and fan noise is increased.
■ The pipes or hoses for laying the exhaust air line 
must consist of non-combustible material.
Round pipes 
An inner diameter of 150 mm, but at least 120 mm, is 
recommended.
Flat ducts 
The inner cross-section must correspond to the 
diameter of the round pipes.
dia. 150 mm ca. 177 cm
2
dia. 120 mm ca. 113 cm
2
■ Flat ducts should not have any sharp deflections.
■ Use sealing strips for deviating pipe diameters.
Checking the wall
■ The wall must be level, vertical and adequately load-
bearing.
■ The depth of the bore holes must be the same 
length as the screws. The wall plugs must have a 
secure grip.
■ The enclosed screws and wall plugs are suitable for 
solid brickwork. Suitable fasteners must be used for 
other structures (e.g. plasterboard, porous concrete, 
poroton bricks).
■ The max. weight of the extractor hood is 40 kg.
Electrical connection
:Warning
Risk of electric shock!
Components inside the appliance may have sharp 
edges. These may damage the connecting cable. Do 
not kink or pinch the connecting cable during 
installation.
The required connection data can be found on the 
rating plate inside the appliance; to do this, remove the 
metal mesh grease filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference 
suppression regulations.
:Warning
Risk of electric shock!
It must always be possible to disconnect the appliance 
from the electricity supply. The appliance must only be 
connected to a protective contact socket which has 
been correctly installed. If the plug is no longer 
accessible following installation of the appliance, or a 
fixed connection is required, an all-pole isolating switch 
must be present on the installation side with a contact 
gap of at least 3 mm. The fixed connection must only 
be installed by an electrician.