SH-300 User’s Manual Connection with PLC
Page 73 of 103
4.12 THINGET XC Series
SH-300 can communicate with THINGET XC series PLC, the communication port is the
programming port of PLC
SH-300 software configuration:
Item Content
SH-300 COM port 9 pin COM port
PLC COM port Programming port
Default parameter
19200bps、8bits、1stop、Even
Station No.
0-255,1 is Windows default
Distance (Max.)
15m
Communication mode
RS232
Cable type Special cable
Inner relay address M0-M7999
Register address R0-R7999
Connection guidance of Special cable
2 RXD
4 RXD
SH-300 side
3 TXD 5 TXD
PLC side
9 pin D shape 8pin Round shape
Female plug male plug
5 GND
8 GND
(when SH-300 communicates with THINGET series PLC you are recommended to use the
programming cable )
The picture for 8 pin Round shape
Female plug