Specifications

4 Communication settings and guide of HMI connecting with controller
loop
0
1
01
Preset reference value LSB
02
Preset reference value MSB
03
DC brake
Do not DC brake
04
Inertial stop
Do not Inertial stop
05
Quickly stop
Do not Quickly stop
06
locking frequency
Do not locking frequency
07
Acc/Dec stop
start
08
Do not reset
reset
09
Do not inching
inching
10
Acc/Dec 1
Acc/Dec 2
11
valid data
invalid data
12
Relay 1 close
Relay 1 open
13
Relay 2 close
Relay 2 open
14
Set LSB
15
Set MSB
16
Do not reverse
reverse
Transducer controller word (FC structure)
Set 0X 30X 40X 50X 60X 7 all to “1” via the method of setting on when window open; Change
the inverter status (start or stop) by control the status of 0X11.
0x2000=0010 0000 0000 0000(binary bit from the 17th to the 32nd), setting the 30th bit to “1” means
- 68 -