Specifications

4 Communication settings and guide of HMI connecting with controller
8-32 FC Port Baud Rate
[0] 2400 Baud
[1] 4800 Baud
*[2] 9600 Baud
8-33 FC Port Parity
*[0] even, 1 stop bit
[1] Odd, 1 stop bit
[2] None, 1 stop bit
[3] None, 2 stop bit
Inverter setting
Please refer to the manual of Danfoss inverter for details
Supported Device
Danfoss Protocol:
Device Bit Address Word Address Format
EEPROM Register(Double Word) ————
EPD0-7998.99999 DDDD.DDDDD
EEPROM Register ————
EPW0-7998.99999 DDDD.DDDDD
RAM Register(Double Word) ————
RMD0-7998.99999 DDDD.DDDDD
RAM Register ———— RMW0-7998.99999 DDDD.DDDDD
Note
1. D indicates decimal; the prefix of RMD\RMW\EPD\EPW is address parameter, the suffix is index
number.
2. Mapping of index address (adding radix point if having index address, index value follow radix point.
Otherwise there’s no radix point):
RMW310.1 is to 3-10, please clicking Menu, to find 3-10 to check.
3. If no index, radix point followed by default zero. As follows RMW122 to 1-22:
- 65 -