Specifications

4 Communication settings and guide of HMI connecting with controller
FBR2_R ------ 1.0-30.22 DDD.DD
FBR3_R ------ 1.0-30.22
DDD.DD
FBR4_R ------ 1.0-30.22
DDD.DD
FBR5_R ------ 1.0-30.22
DDD.DD
FBR6_R ------ 1.0-30.22 DDD.DD
FBR7_R ------ 1.0-30.22 DDD.DD
FBR8_R ------ 1.0-30.22 DDD.DD
FBR9_R
------
1.0-30.22
DDD.DD
FBR10_R
------
1.0-30.22
DDD.DD
FBR11_R ------ 1.0-30.22
DDD.DD
FBR12_R ------ 1.0-30.22 DDD.DD
FBR13_R ------ 1.0-30.22 DDD.DD
FBR14_R ------ 1.0-30.22 DDD.DD
FBR15_R ------ 1.0-30.22 DDD.DD
FBR16_R ------ 1.0-30.22 DDD.DD
FBR17_R
------
1.0-30.22
DDD.DD
FBR18_R
------
1.0-30.22
DDD.DD
FBR19_R ------ 1.0-30.22 DDD.DD
Please refer to the communication protocol for details.
NOTE
1SET C85 ----- Transmission ratedata type
09600evenstopbit 1
19600nonestopbit 2
24800evenstopbit 1
34800nonestopbit 2.
2SET C84 -----setting station No. The value of C84 must be the same as the PLC’s station No.
When connecting multiple instruments, for distinguishing instruments, each instrument must be set
C84 value with a different parameter. .
3Must press “FUNC+PARA” to set the parameter
4PROG. have 19 numbers and SEG have 30 numbers, press DOWN key (sub) and PROG key (add) to
change program number
5 Press “FUNC+PROG” to change the program.----every program must be set firstly and then
communicate will be ok, or else “PLC Response Error” will print;
6After “RUN/HLD” light on, many parameters can’t be modified(e.g. SET) In order to reset, press
“ PROG+RUN/HOLD” .
Modify the parameter at the state of “DISP”, not at the state of “INPUT”
7On the temperature controller, time parameters show number with sexagesimal.
Example it shows 2222 on the screen, but on the controller panel shows 37.02-----37.00*60+2=2222
8PROG’s address setting
FBR1_R indicates prog 1. (e.g. PROG 1) format: DDD.DD. Main address DDD indicates seg No,
subaddress DD indicates parameter value, the correspondence as follows
ExampleFBR1_R address 11.10 indicates PROG 1,SEG 1,T1 2nd
- 352 -