Specifications
4 Communication settings and guide of HMI connecting with controller
GIO
0.0-0.10
2.0-2.07
1.0-1.7 DDD.DD Read Only
CALC ------ 0-9 D Write Only
COMP ------ 0 D Write Only
JC ------ 0-9 DD Write Only
JA ------ 0 D Write Only
CSUB ------ 0 D Write Only
RSUB 0 ------ D Write Only
WAIT ------ 0.0-4.7 DD.D Write Only
STOP 0 ------ D Write Only
◎Cable Diagram
RS232 Communication Cable
Controller terminal
9
pin D
-
SUB
(
male
)
3
TXD
2 RXD
5
GND
com
2
3
TX
2
RX
5 GND
8 TX
7 RX
5 GND
com0
/
com
1
HMI terminal
9pin D-SUB female/male
4.73 THINGET Controller
◎Serial Communication
Series
CPU
Link Module
Driver
THINGET XC XC3-32R-E RS232 on the CPU unit
MODBUS RTU
THINGET Controller
◎System configuration
Series Link Module COM Type Parameter Cable
THINGET XC RS232 on the CPU unit RS232 Setting Your owner cable
◎Communication Setting
THINGET Controller protocol
HMI Setting
Default communication: 19200, 8, even, 1; station: 1
- 330 -