Specifications
4 Communication settings and guide of HMI connecting with controller
Timer Contact
TS 0-511
------
DDDD
Link Relay
B 0-7FF
HHHH
Edge Relay
V 0-1023
------
DDDD
Annunciator
F 0-1023
------
DDDD
Latch Relay
L 0-2047
------
DDDD
Internal Relay
M 0-8191
------
DDDD
Output Relay
Y 0-7FF
HHHH
Input Relay
X 0-7FF
HHHH
File Register
------
ZR 0-65535
DDDDDD
File Register
------
R 0-32767
DDDDD
Index Register
------
Z 0-9
DD
Counter Value
------
CN 0-511
DDDD
Retentive Timer Value
SN 0-511
DDDD
Timer Value
------
TN 0-511
DDDD
Special Link Register
------
SW 0-3FF
HHH
Link Register
W 0-1FFF
HHHH
Special Data Register
------
SD 0-2047
DDDD
Data Register
------
D 0-11135
DDDDD
Q Series CPU port
Device Bit Address Word Address Format
Special Link Relay
SB 00000- 7FFF
------
HHHH
Link Relay
B 00000- 7FFF
------
HHHH
Edge relay
V 00000-32767
------
DDDDD
Annunciator
F 00000-32767
------
DDDDD
Latch relay
L 00000-32767
------
DDDDD
Special Internal Relay
SM 0000-2047
------
DDDD
Internal Relay
M 00000-32767
------
DDDDD
Output Relay
Y 0000-1FFF
------
HHHH
Input Relay
X 0000-1FFF
------
HHHH
Link Register
------
W 00000- 291F
HHHH
Timer Value
------
TN 00000-23087
DDDDD
Counter Value
------
CN 00000-23087
DDDDD
File Register
------
R 00000-32767
DDDDD
Special Link Register
------
SW 0000- 7FF
HHH
Data Register
------
D 00000-25983
DDDDD
Special Data Register
------
SD 0000-2047
DDDD
- 218 -