Specifications

4 Communication settings and guide of HMI connecting with controller
Cable Diagram
RS232 Communication
HMI terminal
9pin D-SUB female\male
Controller port0
8 pin Mini Din (male)
5 TXD
4 RXD
3 GND
com2
3 TX
2 RX
5 GND
8 TX
7 RX
5 GND
com0/com1
TXD
RXD
GND
Controller
Port
1 terminal
HMI terminal
9pin D
-SUB female
/
male
com2
3
TX
2 RX
5
GND
8
TX
7
RX
5 GND
com
0/
com
1
RS485-2 Communication
Controller
Port1 terminal
HMI terminal
9pin D
-SUB female
/male
RS485-
RS
485+
GND
com0/com1
1
RX-
6 RX+
5 GND
4.48 Millenium3
Serial Communication
Series
CPU
Link Module
Driver
Millenium 3 Millenium 3
RS232 on the CPU unit
Millenium 3
RS485 on the CPU unit
System configuration
Series CPU Link Module COM Type Parameter Cable
Millenium 3 Millenium 3
RS232 on the CPU unit RS232
Setting Your owner cable
RS485 on the CPU unit
RS485-2
Setting
Your owner cable
Communication Setting
HMI Setting
Default communication parameters 115200, 7, 1, evenStation1
RS232 Communication:
- 191 -