Device maintenance and repair
5.4 Reinstalling the software
SIMATIC ITP1000
Operating Instructions, 01/2017, A5E37340160-AA
59
"Install Windows" installation program
The language of the installation program and the operating system is preset to English. You
can change the language of the operating system after the installation. You can find
information on this in section: "Setting up the language selection using the Multilanguage
User Interface (MUI) (Page 61)".
Setting up partitions and integrating storage controllers unknown to the operating system
You can set up partitions during the installation process and integrate storage controllers that
are unknown to the operating system. To do so, select "Custom (advanced)" when prompted
for the installation type in the "Install Windows" installation program.
You can set up partitions during the installation process. The recommended minimum size
for Windows 7 system partition varies, depending on the amount of RAM and additional
software that you are going to use. For additional information see: "Setting up partitions in
Windows 7 (Page 60)".
Information for systems with AHCI controller
Data carrier controllers unknown to the operating system must be made known to the
operating system prior to installation in the "Install Windows" installation program.
Requirement
You have copied the relevant controller driver to a USB stick.
Procedure
1. Connect the USB stick with the controller driver to the device.
2. Start the "Install Windows" installation program as described above.
3. Select "Load Drivers" in the Windows installation window.
4. Select the respective driver on the USB stick.