Specifications
50
Ordering Information
SLD6
3-Pole, 600V AC
Catalog
Number
Max.
Cont.
Current
Rating
Cont.
Current
Setting
Long
Time
Delay
Instantaneous
Setting
Short
Time
Pick Up
Short
Time
Delay
Short
Time I²t
Pick Up
Ground
Fault
Pick Up
Ground
Fault
Delay
UL Interrupting Ratings (kA) RMS
Symmetrical Amperes)
Volts AC
120 120/24 240 277 480 600
SLD69300
SLD69400
SLD69500
SLD69600
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
65
65
65
65
35
35
35
35
25
25
25
25
SLD69300G
SLD69400G
SLD69500G
SLD69600G
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
65
65
65
65
35
35
35
35
25
25
25
25
SLD69300NT
SLD69400NT
SLD69500NT
SLD69600NT
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
65
65
65
65
35
35
35
35
25
25
25
25
SLD69300NGT
SLD69400NGT
SLD69500NGT
SLD69600NGT
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
65
65
65
65
35
35
35
35
25
25
25
25
SHLD6
3-Pole, 600V AC
SHLD69300
SHLD69400
SHLD69500
SHLD69600
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
100
100
100
100
65
65
65
65
35
35
35
35
SHLD69300G
SHLD69400G
SHLD69500G
SHLD69600G
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
100
100
100
100
65
65
65
65
35
35
35
35
SHLD69300NT
SHLD69400NT
SHLD69500NT
SHLD69600NT
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
100
100
100
100
65
65
65
65
35
35
35
35
SLD69300NGT
SLD69400NGT
SLD69500NGT
SLD69600NGT
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
100
100
100
100
65
65
65
65
35
35
35
35
SCLD6
3-Pole, 600V AC
SCLD69300
SCLD69400
SCLD69500
SCLD69600
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
200
200
200
200
150
150
150
150
100
100
100
100
SCLD69300G
SCLD69400G
SCLD69500G
SCLD69600G
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
200
200
200
200
150
150
150
150
100
100
100
100
SCLD69300NT
SCLD69400NT
SCLD69500NT
SCLD69600NT
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
200
200
200
200
150
150
150
150
100
100
100
100
SCLD69300NGT
SCLD69400NGT
SCLD69500NGT
SCLD69600NGT
300
400
500
600
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
200
200
200
200
150
150
150
150
100
100
100
100
Ampere Rating Catalog Number
300 NO3SJD
400 NO4SJD
500 NO5SLD
600 NO6SLD
Note: “G” suffix in catalog number denotes circuit breaker for 3 phase, 3 wire circuits.
For 3 phase, 4 wire, order correct 4th wire (neutral) transformer as separate and
additional item.
For 100% rated breakers, an “H” is added at the end of the normal catalog
number, i.e. SHLD69600NGTH.
Use copper only terminal connectors for LD frame solid state 100% rated circuit
breakers .
Neutral Transformers (Not to be used on Sensitrip II)
Circuit Breaker Catalog Numbers