Operating instructions

Assigning device parameters
5.3 Configuration settings of the device
Industrial Thin Client ITC1200, ITC1500, ITC1900, ITC2200
Operating Instructions, 04/2013, A5E03474888-02
65
If "No proxy" is selected, there is no proxy server request, and a direct connection to the
Internet or an intranet will be established instead.
Under "Port", specify the internal port at which the proxy server can be reached: The
default is 8080.
In "Home page", specify an Internet address that will be called automatically when the
web browser starts.
With "Character encoding", you specify the character set that is used by the web browser
if a web page does not provide any information about the character set to be used. The
character set "UTF-8" is set by default. You can have the appropriate character set
determined "automatically". If characters are represented incorrectly, you can also
change to "ISO-8859-1".
You can enable or disable the Java support by the browser with Java. For security
reasons, Java is disabled by default.
Proxy bypass
You can make the following entries in the "No proxy for" field:
Object for which
no proxy is to be
used
Content of the
input field "No
proxy for"
Example Comments
Domain Suffix of the
domain
".siemens.com,
siemens.com"
Both suffix variants must be
entered in order to exclude an
entire domain.
Host name
(without
domain)
Host name only "MyWinPC" Excludes "MyWinPC.
Host name
(with domain)
Host name and
domain
"MyWinPC.siemens.com" Excludes "MyWinPC.
IP address IP address "192.168.1.0" Excludes the device with the IP
address "192.168.1.0".
Network IP address range "192.168.1.0/24" Excludes all devices with an IP
address in the range from
"192.168.1.0" to ""192.168.1.24"
Placeholder characters are not permitted, e.g. "*" or "192.168.*.*".
No entries are set as default.
The "localhost" and "127.0.0.1" objects are always excluded. No proxy is used for these
objects.