Personal Computer User Manual

Description
3.5 Design
SIMATIC IPC427C
18 Operating Instructions, 04/2009, A5E02414743-01
3.5.2 Connection components
Ports and power supply
Location of connection elements (version with PROFIBUS or CAN)
Pos Name Description
24 VDC Connection for a 24 V DC power supply
DVI/VGA DVI/VGA connection for CRT or LCD monitor with DVI interface
USB 4 USB 2.0 connections, high-speed / low current
PN/IND. ETHERNET RJ45 Ethernet connection 1 (exclusive PCI interrupt) for 10/100/1000 Mbps
PN/IND. ETHERNET RJ45 Ethernet connection 2 (shared PCI interrupt) for 10/100/1000 Mbps
PROFIBUS DP/MPI
CAN fieldbus
PROFIBUS DP/MPI interface (RS 485 isolated), 9-pin Cannon socket or CAN fieldbus
(on request)
COM1 Serial port (RS232) 9-pin Cannon connector
USB strain-relief
fastener
The USB strain relief must be fastened to the device enclosure with an oval-head screw
(M4 thread). The USB cables can be fastened to the strain-relief assembly with a cable
tie.
PE terminal The PE terminal (M4 thread) must be connected to the protective ground conductor of the
plant, in which the device is to be installed. The minimum conductor cross-section may not
be less than 2,5 mm
2
.
Location of the connection elements (second COM interface)
Pos Designation Description
COM2 Serial port (RS232) 9-pin Cannon connector