Specifications
IP 240 Position Decoding
DB12 LEN=73
0: KH = 0000;
1: KS =' '; MACHINE-READABLE PRODUCT CODE OF THE MODULE
4: S =' '; Version of the firmware
7: KS =' '; Hardware version
8: KH = 0000; Error flags for
9: KH = 0000; hardware and
10: KH = 0000; communications errors
11: KH = 9001;
12: KH = 00FF;
13: KH = 0000; Parameter assignment error message
14: KH = 0000;
15: KH = FF05;
16: KH = 0080;
17: KM = 0000000000000000; Control bits
18: KM = 0000000000000000; Status bits
19: KM = 1000000000000001; Status bits (RF1-REF8)
20: KM = 1000000000000000; Interrupt request byte channel 1
21: KM = 0000000000000000; Interrupt request byte channel 2
22: KH = 0000; Hysteresis
23: KY = 001,012; Mode and DB number
24: KH = 0000;
25: KH = 0000;
26: KH = 0000;
27: KH = 0000;
28: KH = 0000;
29: KM = 0000000010000000; Bits for tracks to used
30: KH = 0000; Actual value in BCD code
31: KH = 1942;
32: KM = 0000000000000000; Actual value in binary code
33: KM = 0000011110010110;
34: KH = 0001; Initial value track 1
35: KH = 0400;
36: KH = 0002; Final value
37: KH = 2000;
38: KH = 0002; Initial value track 2
39: KH = 2000;
40: KH = 0002; Final value
41: KH = 6000;
42: KH = 0002; Initial value track 3
43: KH = 6000;
44: KH = 0003; Final value
45: KH = 4000;
46: KH = 0003; Initial value track 4
47: KH = 4000;
48: KH = 0003; Final value
49: KH = 5000;
50: KH = 0003; Initial value track 5
51: KH = 5000;
52: KH = 0004; Final value
53: KH = 6000;
54: KH = 0004; Initial value track 6
55: KH = 6000;
56: KH = 0006; Final value
57: KH = 7000;
58: KH = 0006; Initial value track 7
59: KH = 7000;
60: KH = 0007; Final value
61: KH = 4000;
62: KH = 0109; Initial value track 8
63: KH = 9999;
64: KH = 0000; Final value
65: KH = 0000;
66: KH = 0100; Zero offset value
67: KH = 7450;
68:
EWA 4NEB 811 6120-02a