Specifications

Positioning IP 240
OPERAND SYMBOL COMMENTARY
FY 65 ERROR REASON FOR SETTING GROUP ERROR FLAG (F 64.7)
F 65.0 ERR00 REF. POINT APPROACH TERM. WITHOUT SYNC
F 65.1 ERR01 NOT ENOUGH DISTANCE BETW. ACTVAL AND SETPOINT
F 65.2 ERR02 TARGET RANGE NOT REACHED
F 65.3 ERR03 TARGET RANGE EXITED (ZBV)
F 65.4 ERR04 PERM. POSITIONING TIME EXCEEDED
F 65.5 ERR05 INTERRUPTS DRB, NPU, OVF
F 65.6 ERR06 ACTVAL NO LONGER SYNCHRONIZED
F 65.7 ERR07 PAFE GROUP ERROR (-> FY200)
FY 66 FBPOS FEEDBACK POS. NUMBER (DR28)
FY 67 EJECTPOS NEXT EJECT POS. TO BE APPROACHED
FW 68 INTCH1 INTERR. REQUEST BYTES F. CHANNEL 1
F 68.0 UEB IR COUNTER IN OVERRANGE
F 68.1 NPU IR ZERO MARK ERROR
F 68.2 DRB IR WIREBREAK/SHORT-CIRCUIT
F 68.3 UBS IR FINAL VALUE OVERWRITTEN
F 68.4 ZBV IR TARGET RANGE (BEE3) EXITED
F 68.5 RIU IR CUT-OFF RANGE (BEE2) EXITED
F 68.6 F 68.6 --
F 68.7 F 68.7 --
F 69.0 F 69.0 --
F 69.1 RIC STATUS FLAG
F 69.2 BE1 IR BEE1 ENTERED
F 69.3 BE2 IR BEE2 ENTERED
F 69.4 BE3 IR BEE3 ENTERED
F 69.5 MES IR FINAL VALUE STORED
F 69.6 F 69.6 --
F 69.7 F 69.7 --
10-100