Specifications
Counting IP 240
FB 39 LEN=37
NETWORK 1 0000 WRITE FLAGS
FB39 WRITES THE STATES OF FLAG WORDS 200 TO 254 SAVED WITH FB 38 BACK
TO THE FLAG WORDS. THE DATA BLOCK SPECIFIED MUST COMPRISE AT LEAST 30 DATA WORDS
(DW0 TO DW29).
NAME :LOAD FLG
BEZ :DBNR I/Q/D/B/T/C: B
0008 :B =DBNR
0009 :***
NETWORK 2 000A
000A :L KF +0 INITIALIZE THE POINTERS
000C :T DW 28 DATA WORD POINTER
000D :L KF +200
000F :T DW 29 FLAG WORD POINTER
0010 M001 :DO DW 28
0011 :L DW 0
0012 :DO DW 29
0013 :T FW 0
0014 :L DW 28 INCREMENT THE POINTERS
0015 :ADD BF +1
0016 :T DW 28
0017 :L DW 29
0018 :ADD BF +2
0019 :T DW 29
001A :L KF +254 ALL FLAG WORDS UP TO
001C :L DW 29 AND INCLUDING FW254
001D :>=F RELOADED ?
001E :JC =M001
001F :BE
8-24