Specifications
Position Decoding IP 240
FB 28 LEN=81
0039 REF8 :
003A :AN F 16.7 REF8 (CUTOFF POINT)
003B :JC =OUTP
003C :S F 12.6 -FIN POINT BIT FOR FINAL POINT FORWARD REACHED
003D :JU =OUT1
003E FOR2 :
003F :A F 16.7 REF8 (INITIAL POINT)
0040 :S F 12.7 -INT POINT
0041 :JC =OUT1
0042 :BEU
0043 DRBR :
0044 :S F 11.7 -WIREBREAK
0045 OUT1 :
0046 :R Q 12.4 -HEATING
0047 :L KH 0000
0049 OUTP :
004A :T FW 14 -ANALOG VAL
004B :BE
FY 3 = AUX BYTE2 SCRATCH FLAG BYTE INTERRUPT SERVICE ROUTINE
FW 16 = AUX WORD4 AUXILIARY FLAG WORD - INTERRUPT SERVICE ROUT.
(STATUS BITS)
F 12.4 = BACK ACTIV BACKWARD TRAVERSE PROGRAM ACTIVE
F 12.2 = FORW ACTIV FORWARD TRAVERSE PROGRAM ACTIVE
F 12.6 = FIN POINT FINAL POINT OF THE FORWARD TRAVERSE PROGRAM REACHED
F 12.7 = INT POINT INITIAL POINT/ORIGINAL POSITION REACHED
F 11.7 = WIREBREAK WIREBREAK/SHORT-CIRCUIT IN ENCODER (FB28)
Q 12.4 = HEATING HEATING ON (CONTACTOR + INDICATOR)
FW 14 = ANALOG VAL ANALOG VALUE TO BE OUTPUT IN UNITS (UP TO 1024)
7-56
EWA 4NEB 811 6120-02a